Activating The Dry Charge Battery (If Applicable); Connecting The Battery - Miller Electric Big Blue 300 Owner's Manual

Engine driven welding generator
Hide thumbs Also See for Big Blue 300:
Table of Contents

Advertisement

5-4. Activating The Dry Charge Battery (If Applicable)

1
Tools Needed:

5-5. Connecting The Battery

Tools Needed:
1/2 in
OM-4433 Page 22
3
2
5 A For 30 Minutes
OR
30 A For 12 Minutes
4
+
!
!
Always wear a face shield,
rubber gloves and protective
clothing when working on a
battery.
Remove battery from unit.
5
Vent Caps
6
Sulfuric Acid Electrolyte
(1.265 Specific Gravity)
7
Well
Fill each cell with electrolyte to
bottom of well (maximum).
!
Do not overfill battery cells.
Wait ten minutes and check electro-
lyte level. If necessary, add electro-
lyte to raise to proper level. Reins-
tall vent caps.
8
Battery Charger
!
Read and follow all instruc-
tions supplied with battery
charger.
Charge battery for 12 minutes at 30
amperes or 30 minutes at 5 am-
peres. Disconnect charging cables
and install battery.
.
When electrolyte is low, add
only distilled water to cells to
maintain proper level.
drybatt1 6/05 − S-0886
.
Close door after connecting battery.
Connect Negative (−) Cable Last.
+
803 563 / Ref. 217 357-A / S-0756-C

Advertisement

Table of Contents
loading

Table of Contents