4-1. Dimensions And Weight

Hole Layout Dimensions
A
11-3/4 in (298 mm)
B
1-11/16 in (42 mm)
C
15-3/4 in (400 mm)
D
19-3/32 in (485 mm)
E
8-11/16 in (221 mm)
F
1-17/32 in (39 mm)
G
1/4-20 UNC -2B thread
Weight
80 lb (36.3 kg)

4-2. Selecting a Location

!
Do not move or operate unit
where it could tip.
Location
18 in
(460 mm)
SECTION 4 − INSTALLATION
F
D
C
C
B
1
4
3
18 in
(460 mm)
A
E
G
12-1/2 in
(318 mm)
804 801-A
1
Movement
2
24 in
(610
(610
mm)
17 in
(432 mm)
1
Lifting Handles
Use handles to lift unit.
2
Hand Cart
Use cart or similar device to move
unit.
3
Rating Information
Use rating information on rear panel
to determine input power needs.
4
Line Disconnect Device
Locate unit near correct input
power supply.
!
Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.
loc_2 3/96 - Ref. ST-151 556 / Ref. 803 691-C