TECHNICAL SPECIFICATIONS -

Product Ordering
Input AC
Name Information Voltage
208-230/
380-400/
EX350i
K1757-1
415-460/
1 & 3 Phase
60/50 Hz
* Overall Length Including Handle, 27.8" (706mm).
Recommended Fuse Sizes Based On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Voltage
Phases
200
1
208
1
230
1
380
1
400
1
415
1
460
1
575
1
200
3
208
3
230
3
380
3
400
3
415
3
460
3
575
3
Note 1. Not rated is indicated by 4-x's in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
CURRENT
100%
275
60%
350

INSTALLATION

EX350i
INPUT AC VOLTAGE & DC OUTPUT
Rated DC Output
Amps/Volts/Duty Cycle
200
350A / 34V / 60%
575
275A / 31V / 100%
EX350i INPUT CURRENT
Output
275Amps@
350Amps@
31Volts(100%)
34Volts(60%)
Not
Not
Recommended
Recommended
70
62
Not
Not
Recommended
Recommended
Not
Not
Recommended
Recommended
38
34
27
37
36
31
21
20
19
17
14
LENGTH UP 61m (200 FT)
Output
Range
(continuous)
AMPS
5-425
Recommended
Line Cord
AWG[IEC] SIZES
---
94
2
85
4
---
---
54
6
42
8
37
8
50
8
50
6
42
8
28
8
27
8
26
8
23
8
18
8
1/0
1/0
EX350i
Weight
Dimensions
with Cord
HxWxD
Factory
82.5lbs
(37.4 kg)
14.7"x12.5"x27.8"*
Construction
81.5lbs
(373x318x706*)mm
(36.9 kg)
Size Fuse Size
---
125A
125A
---
---
80A
70A
50A
80A
80A
70A
50A
50A
50A
50A
35A
61-76m (200-250 FT)
1/0
2/0
A-1
Notes
Note 1
Note 2
Note 2
Note 1
Note 1
Note 2
Note 2
Note 2

Advertisement

Table of Contents