Remote 14 Receptacle Information; Connecting Remote Control - Miller Electric Dimension NT 450, NT 500 Owner's Manual

Arc welding power source
Table of Contents

Advertisement

4-10. Remote 14 Receptacle Information

24 VOLTS AC
115 VOLTS AC
REMOTE
OUTPUT
OUTPUT
CONTROL
A/V
AMPERAGE
AMPERAGE
VOLTAGE
GND
GND
*The remaining sockets are not used.

4-11. Connecting Remote Control

Socket*
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac contactor control circuit.
I
115 volts ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac contactor control circuit.
C
Output to remote control; +10 volts dc in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from remote control.
M
Remote mode select.
F
Current feedback; +1 volt dc per 100 amperes.
H
Voltage feedback; +1 volt dc per 10 arc volts.
G
Circuit common for 24 and 115 volts ac circuits.
K
Chassis common.
A
J
K
I
B
C L N
H
M
D
G
F
E
OR
Socket Information
!
Turn off power before con-
necting to Remote 14 recep-
tacle.
1
Remote 14 Receptacle RC14
Connect remote control to RC14.
1
OR
Ref. 800 166-D / Ref. S-0004-A / S-0750