2-7. Remote 14 Receptacle Information

A
K
K
B
C L N
M
D
E
*The remaining sockets are not used.

2-8. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose – no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
OM-293 Page 12
J
I
I
H
G
24 VOLTS AC
24 VOLTS AC
F
115 VOLTS AC
115 VOLTS AC
Ref. 121 470-E / Ref. 192 412
1
2
Time-Delay
Normal Operating 3
Socket*
A
24 volts ac. Protected by circuit breaker CB2.
B
Contact closure to A completes 24 volts ac con-
tactor control circuit.
I
115 volts ac. Protected by circuit breaker CB1.
J
Contact closure to I completes 115 volts ac con-
tactor control circuit.
G
Circuit common for 24 and 115 volts ac circuits.
GND
K
Chassis common.
Socket Information
200
230
460
46
40
20
50
50
25
70
60
30
8
8
12
89
118
188
(27)
(36)
(57)
8
10
12