Volt-Ampere Curves - Miller Electric Dimension NT 450, NT 500 Owner's Manual

Arc welding power source
Table of Contents

Advertisement

4-3. Volt-Ampere Curves

90
80
70
60
50
40
30
20
10
0
0
90
80
70
60
50
40
30
20
10
0
0
100
OM-2252 Page 14
A. CC Mode
100
200
B. CV Mode
200
300
300
400
DC Current
400
500
DC Current
Volt-ampere curves show
mum and maximum voltage and
amperage output capabilities of
unit. Curves of other settings fall be-
tween curves shown.
500
600
600
700
800
va_curve1 − 4/95 − 212 111-A / 212 112-A