Remote 14 Receptacle Rc14 Information And Connections; Remote 14 Socket Information - Miller Electric ProHeat 35 Owner's Manual

Miller electric owner's manual welding generator proheat 35
Table of Contents

Advertisement

4-8. Remote 14 Receptacle RC14 Information and Connections

2
1

4-9. Remote 14 Socket Information

Socket
A
Remote Contactor
Remote Contactor
B
C
D
Remote Output Control
Remote Output Control
E
G
F, J
Power Source Limit
H
I
L
Remote Metering
Remote Metering
M
N
K
OM-222 166 Page 16
A
J
K
I
B
C L N
H
M
D
G
F
E
+24 volts dc.
Contact closure to A completes 24 volts dc contactor control circuit.
Command reference; +10 volts dc.
Control circuit common.
Input command signal (potentiometer wiper or 0 to +10 volts dc).
Not used.
Absence of internal contact closure between F and J signals power source error to remote
control device.
Not used.
Actual frequency output signal (1 volt/10 kHz).
Average power output signal (1 volt/10 kW).
Voltage output signal RMS (1 volt/100 volts).
Total current output signal RMS (1 volt/100 amperes).
Chassis common.
Ch
i
1
Plug
2
Threaded Collar
3
Keyway
4
Remote 14 Receptacle RC14
3
(See Section 4-9)
To connect to receptacle, align key-
way, insert plug and tighten
threaded collar.
4
2
1
Socket Information
803 993-C

Hide quick links: