Stopping The Generator; Subsequent Starting Of The Generator - Wen 56200i Instruction Manual

2000w inverter generator
Hide thumbs Also See for 56200i:
Table of Contents

Advertisement

IDLE CONTROL SWITCH (ESC)
This generator is equipped with an Idle Control Switch. En-
gaging the switch will automatically adjust the engine speed.
When an electrical device comes on line, the generator en-
gine will automatically speed up to supply the power needed
and will slow down as the need decreases. The variable
engine speed can reduce fuel consumption and noise level.
Keep this switch engaged when the power load requirement
is less than 1000W. Do not engage the Idle Control Switch
when the total load is more than 1000W. The generator
engine must run at full speed to supply the required power
for anything over 1000W.
TO STOP THE GENERATOR
1. Turn off all electrical devices prior to unplugging them from the generator. Unplugging running devices
can cause damage to the generator.
2. Turn the 3-in-1 knob to the "OFF" position.
3. Close the vacuum relief valve on top of fuel cap. Rotate counterclockwise to the "OFF" position.
WARNING: Allow the generator to cool for several minutes before touching areas that become hot dur-
ing use.
CAUTION: Allowing gasoline to sit in the fuel tank for long periods of time can make it difficult to start the
generator in the future. Never store the generator for extended periods of time with fuel in the fuel tank. Refer to
Generator Storage Section.

SUBSEQUENT STARTING OF THE GENERATOR

If this is not the first time using the generator, the user should take the following steps to prepare it for operation.
IMPORTANT: At this point the user should be familiar with the procedures described in
the section titled "Using the Generator for the First Time." If the user has not yet read
this section, go back and read it now.
Step 1 - CHECK THE OIL
Oil consumption is normal during generator use. The generator is equipped with a low oil pressure shutoff to
protect it from damage. The oil level of the engine should be checked before each use to ensure that the engine
crankcase contains sufficient lubricant.
12
STARTING THE GENERATOR

STOPPING THE GENERATOR

Figure 5 - Control Panel
Idle control
switch

Hide quick links:

Advertisement

Table of Contents
loading