3-1. Installing Work Clamp

Tools Needed:
3/8, 7/16 in

3-2. Installing Welding Gun And Changing Polarity

Tools Needed:
5/16 in
SECTION 3 – INSTALLATION
1
6
5
.
Follow wire manufacturer's recommendation.
Flux Cored Wires
(FCAW–Without Gas)
5
Straight Polarity
DCEN
2
1
2
3
4
Solid Steel Or
Aluminum Wires
(GMAW–With Gas)
Reverse Polarity
DCEP
3
4
1
Insulator
2
Bolt
3
Smaller Hole
4
Work Clamp Tabs
Bend tabs around work cable.
5
Work Cable From Unit
6
Nut
Ref. ST-025 190-D
1
Drive Assembly
2
Gun Securing Bolt
3
Gun End
Loosen securing bolt. Insert gun
end through opening until it bottoms
against drive assembly. Tighten
bolt.
4
Gun Trigger Plug
Insert plug into receptacle, and
tighten threaded collar.
5
Jumper Links
Place jumper links in position
shown for desired polarity.
Close door.
Ref. ST-801 987