Technical Specifications; Standard Installation; Corner Installation - Kemlan XL Installation & Operating Instructions Manual

Freestanding
Table of Contents

Advertisement

MINIMUM CLEARANCES FOR THE KEMLAN XL SOLID FUEL
APPLIANCE INSTALLED WITH A DEFAULT FLUE KIT

STANDARD INSTALLATION

B
E
A - 100mm
D - 3200mm
B - 550mm
E - 945mm
C - 150mm
F - 620mm
*As per Clause 3.3.3 of AS/NZS 2918 for floor protector
construction requirements.
Where a sample appliance installation (or prototype
installation) has not been tested, the floor protector
shall extend either to a distance of not less than 500mm
(measurement C) beyond any part of the appliance or a
lesser distance at which it forms a abutment with a wall or
heat shield (subject to the requirements of Clause 3.2).
Glass viewing area
- 602mm wide x 302mm high
Flue pipe
- ø150mm – top exit
Shipping weight
- 215kg
All dimensions shown are approximate. Check all
dimensions accurately before installation. Before
installing refer to the installation instructions.
In line with our policy of continuous improvement, we
reserve the right to alter specifications without notice.
CONSTRUCTION
- 6 & 8mm heavy duty steel firebox – fully welded
- 25mm thick firebrick lined floor
- 19mm ceramic lined sides and baffle
PERFORMANCE
- Heating capacity – 220-320m2 (23-33 squares)
- Peak heat output – 21.6kW
- Average output – 2.0g/kg
- Average efficiency – 61%

TECHNICAL SPECIFICATIONS

A
D
I*
H
G - 1200mm
H - 1060mm
I* - 500mm

CORNER INSTALLATION

G
C
NOTE:
The floor protector consists of a 12mm thick cement fibre sheet
which has a thermal resistance of 0.8² k/W, per 4mm thick sheet
Heating capacity of this appliance is given as a guide only
and may vary depending on the climate zone and type
of dwelling (floor plan and degree of insulation). Consult
your local authorised distributor to determine realistic
expectations for your home.
Heat output and fuel consumption of this appliance
is dependent on the moisture content, size, loading
geometry and the type of hardwood used.
The appliance complies to the safety standards AS/NZS
2918. When in use some parts may become hot. A
suitable fireguard is recommended where the very young,
elderly or infirm are concerned.
C
F
F
I*
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents