Start Up Flush; Figure 6. Filter Configuration Model "F - Global Water G4 Counter Top Operation Manual

Hide thumbs Also See for G4 Counter Top:
Table of Contents

Advertisement

Start-Up Flush
Open the right side panel to access filter assembly. Then, turn the
water off at the ball valve on at the at the water connection. This brings
water to the ball valve. Disconnect the tube from the second stage carbon
filter (red circle in figure bellow), and place a cup or pan right underneath
the hole to catch water. Open ball valve inside the cooler 1/4-turn. The
handle in line with the tube is "on." Let water flow through filters into the
bucket or pan to push out air and carbon fines. When water runs clear, turn
off the ball valve and re-connect the tube to the filter.
Turn the water on to the filter system by opening the ball valve inside the
cooler 1/4-turn (handle in line with tube is "on"). Check all connections to
assure there are no leaks.
Figure. 6 Filter configuration model "RO" with side panel removed.