PROBLEM
No Power
Cold Water not cold
enough
Hot Water doesn't flow
out of spigot
Won't cool
Panel not lit
No hot water at start up
Note - In the event of problems beyond the scope of the troubleshooting described in the manual,
please call your selling dealer.
17 |
P a g e
Trouble Shooting Guide
CAUSE
No electric current
flowing.
The cooler is placed too
close to the wall.
Wire Condenser on
backside is dusty.
Compressor does not
have enough
refrigerant.
Air may be trapped in
the line.
Controls not set.
No power.
Hot tank overheat
protection sensor
tripped.
SOLUTION
Make sure the cooler is
plugged in and check
for improper
connections.
Provide a minimum of
a five inch space
between wall and back
of dispenser.
Clean wire condenser
every three months.
Place cooler in a well-
ventilated area.
Adjust thermostat.
Hold the spigot down
for 30 seconds to
relieve air.
Turn cold temperature
switch "on" at back.
Check that the power
cord is in the socket
and turn on the cold/hot
buttons on the back of
the cooler to the "on"
position.
1. Unplug cooler.
2. Let sensor cool down
for one hour.
3. Reach through
cooling grill with pencil
or narrow screwdriver
to press nude color
reset button on upper
sensor located on the
hot tank.

Hide quick links: