Miele ESW 5088-14 Operating And Installation Instructions page 41

Built-in food warming drawer
Hide thumbs Also See for ESW 5088-14:
Table of Contents

Advertisement

Connection should be made via a suitable switched socket or
a double pole fused spur connection unit which complies with
national and local safety regulations and the on/off switch
should be easily accessible after the appliance has been
built in.
If the switch is not accessible after installation (depending on
country) an additional means of disconnection must be
provided for all poles.
For extra safety it is advisable to install a suitable residual
current device (RCD).
When switched off there must be an all-pole contact gap of at
least 3 mm in the isolator switch (including switch, fuses and
relays).
Important U.K.
The appliance is supplied for connection to a 230-240 V,
50 Hz supply with a 3-core cable.
The wires in the mains lead are coloured in accordance with
the following code:
Green/yellow = earth
Blue
= neutral
Brown
= live
WARNING
THIS APPLIANCE MUST BE
EARTHED
Electrical connection
41