ENGLISH
DESCRIPTION
This appliance is equipped with a completely automatic system (Advanced Sensor Control) capable to
manage all the functions of your hood. Thanks to the ASC, the air in the kitchen is costantly clean and odour
free without any manual intervention. The advanced sensor catches all sort of vapours, smokes and odours
caused by the cooking process. The ASC also captures an abnormal presence of GAS.
The unit can be found in filtering hoods, ducting hoods or in hoods with an outside motor. In the Filtering version
the air and the kitchen fumes that are conveyed by the apparatus are depurated by the charcoal filter and put back into
the room through the small grilles of the ventilation flue (Fig. 1). ATTENTION: When using the filtering version, a charcoal
filter and an air baffle (Fig. 1A) must be used, which placed at the top of the structure, allows the air to recycle back into
the room. In the Ducting version, cooking vapours and odours are conveyed straight outside by a disposal duct which
passes through the ceiling (Fig. 2). In the hoods with an outside motor (Fig. 3), a vacuum suction unit must be connected;
this exhaust will operate separately, conveying the exhaust air through the unit. Only use vacuum units suggested in
the original catalogue.

INSTALLATION

ATTENTION: Two persons are required for proper installation; the unit should be installed by a qualified operator.
Also follow carefully each step of the assembly instructions, and once installation has been completed, make sure
that the hood is firmly secured in place.
To facilitate installation, before starting remove the grease filters: press inward on the clamp at the handle and pull
the filter downward (Fig. 4).
For assembling it is essential to: – Prepare the connection to the mains within the telescopic flue. – If your unit is
installed in an ducting hood or in a hood with outside motor, prepare the air exhaust hole.
When installing ducting hoods and hoods with outside motor, to achieve the best possible conditions use an air exhaust
pipe that : is as short as possible, has a minimum of curves (maximum angle: 90°), is made of a material that complies
with the standards (which vary from nation to nation) and iv) is smooth on the inside. It is also advisable to avoid any
drastic changes in pipe section (diameter: 150 mm).
ASSEMBLING - Using the special drilling template, drill the holes for fixing to the ceiling on the vertical side of your
hob. Carefully observe all the indications for final positioning of the apparatus. Take into account that one of the template
axes must correspond to the axis of the hood controls. Fix the bracket to the ceiling using the screws and screw anchors
provided (Fig. 5). Be careful, because the position of the bracket determines the final position of the apparatus: the side
with the slot B corresponds to the side opposite the commands. Mount the plate of the electrical system fixing it with 3
screws and 2 metal washers (Fig. 6).
Ducting version and version with an external motor: Fix the telescopic structure to the bracket by means of 4 screws
(provided), running the air evacuation pipe through the telescopic structure and the electric power cable through the special
hole in the bracket (Fig. 7). Adjust the height of the telescopic structure by means of the four retaining screws C (Fig.8),
taking into account that the height of the hood is 86 mm and that the distance between the hood and the hob must be
at least 650 mm (Fig. 9). Take the upper pipe (with the round slots) and fit it on the telescopic structure with the slots
facing downwards; fit the pipe to the bracket with 2 screws (Fig. 10). Take the lower pipe and fit it in the same manner
as before; slide it to the top and stop it in that position using a screw inserted in the hole of the upper pipe as a catch
(Fig. 11). Fit the hood to the telescopic structure by means of 4 screws (provided) – Fig. 12.
D (Fig. 12) fix the air evacuation pipe to the air outlet mouth of the hood.
Only for models with outside motor (Fig. 13): plug the hood into the outside control unit using the special terminal block:
remove wire clamp A and lid B from the wiring junction box; secure the wire connecting the control unit to terminal C; then
replace wire clamp A and lid B on the wiring junction box; the other end of the wire is secured to the terminal block on
the outside control unit.
Make the electrical connection by means of the power cable. Remove the screw used as catch and slide the lower pipe
downwards, placing it gently on the apparatus. Installation is now complete and the anti-grease filters can be remounted.
Filtering version: Fix the telescopic structure to the bracket by means of 4 screws (provided), running the electric power
cable through the special hole in the bracket (Fig. 7). Adjust the height of the telescopic structure by means of the four
retaining screws C (Fig. 8), taking into account that the height of the hood is 86 mm and that the distance between the
hood and the hob must be at least 650 mm (Fig. 9). Insert the air baffle in the structure (Fig.14). Through the openings
E (Fig.14), fit the flange to the baffle locking it with a turning movement. Fix a flexible pipe to the flange for air evacuation
(Fig. 15). Take the upper pipe (with the round slots) and fit it on the telescopic structure with the slots facing upwards;
fit the pipe to the bracket with 2 screws (Fig. 16). Take the lower pipe and fit it in the same manner as before; slide it to
the top and stop it in that position using a screw inserted in the hole of the upper pipe as a catch (Fig. 11). Fit the hood
to the telescopic structure by means of 4 screws (provided) – Fig. 17. Through the openings D, mount the flange (provided)
on the air outlet mouth of the hood (Fig. 17). Then fit the air evacuation pipe to the flange. Make the electrical connection
by means of the power cable. Remove the screw used as catch and slide the lower pipe downwards, placing it gently on
the apparatus. Install the charcoal filter clipping the 2 filter clips into place (Fig. 18) and turn the filter upwards. Installation
is now complete and the anti-grease filters can be remounted.