Daikin Siesta ARCWLA Operating Manual page 36

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
HATA KODU
DIŞ HAVA TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK
H9
J1
BASINÇ SENSÖRÜNDE HATA
KOMPRESÖR BOŞALTMA BORUSU TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK/YANLIŞ YERLEŞTİRDİ
J3
J5
EMME BORUSU TERMİSTÖRÜ KISA/AÇIK
DIŞ ISI EŞANJÖRÜ TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK
J6
J7
ALT SOĞUTMA ISI ESANJÖRÜ TERMİSTÖRÜ KISA/AÇIK
SIVI BORUSU TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK
J8
J9
GAZ BORUSU TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK
İNVERTÖR DIŞ ÜNİTE PCB HATASI
L1
DIŞ KONTROL KUTUSU AŞIRI ISINDI
L3
L4
ISI HAZNESİ AŞIRI ISINDI
IPM HATASI/IGBT HATASI
L5
L8
İNVERTÖR KOMPRESÖRÜNDE AŞIRI AKIM
KOMPRESÖR AŞIRI AKIM ÖNLEME
L9
LC
İLETİŞİM HATASI (DIŞ KONTROL PCB'Sİ VE İNVERTÖR PCB'Sİ)
AÇIK FAZ VEYA VOLTAJ DENGESİZLİĞİ
P1
P4
ISI HAZNESİ TERMİSTÖRÜ KISA DEVRE YAPTI/AÇIK
KAPASİTE AYARI HATASI
PJ
U0
YETERSİZ GAZ
DC GERİLİMİ ARALIK DIŞI
U2
U4
İLETİŞİM HATASI
İLETİŞİM HATASI (DIŞ KONTROL BDP VE IPM BDP)
U7
UA
KURULUM HATASI
BORU VE KABLO TERTİBATI UYUŞMUYOR/YANLIŞ KABLO TERTİBATI/YETERSİZ GAZ
UF
UH
ANTİFRİZ (DİĞER ODALAR)
NOT
1. Kısa bir uyarı sesi ve sonra ardarda iki uyarı sesi uygun olmayan kodları gösterir.
2. Kod göstergesini iptal etmek için, ON TIMER CANCEL (Zaman Ayarı Açık İptal) düğmesini veya
OFF TIMER CANCEL (Zaman Ayarı Kapalı İptal) düğmesini 5 saniye basılı tutun. Ayrıca, kod
göstergesi düğmeye 1 dakika basılı tutulduğunda kendini iptal eder.
07-TR-OM-GS02-0411(0)-Siesta.ind28 28
07-TR-OM-GS02-0411(0)-Siesta.ind28 28
ANLAMI
28
5/20/11 4:58:04 PM
5/20/11 4:58:04 PM