Fuel Specifi Cations; Before Lighting Appliance - Heat & Glo LUX36 Owners Manual Care And Operation

Owners manual care and operation for gas fireplace
Hide thumbs Also See for LUX36:
Table of Contents

Advertisement

C. Fuel Specifi cations
WARNING! Risk of Fire or Explosion! Appliance must
be set up for compatible gas type!
The LUX36 and LUX42 models are made for use with
Natural Gas only. Conversion is not allowed.
D. Before Lighting Appliance
Before operating this fi replace for the fi rst time, have a
qualifi ed service technician:
• Verify all shipping materials have been removed from
inside and/or underneath the fi rebox.
• Review proper placement of media and/or other
decorative materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT op-
erate fi replace with fi xed glass assembly removed.
Heat & Glo • LUX36, LUX42 Owner's Manual • 2287-981 Rev. B • 3/14
FIREPLACE OPENING
Figure 3.4 Wall Surface Temperatures
CEILING
150°F
160°F
52 IN. MIN.
155°F
46 IN.
160°F
40 IN.
34 IN.
165°F+
28 IN.
180°F+
22 IN.
230°F+
16 IN.
10 IN.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT