REMOTE POWER
ALARM
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment. Printed in USA.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment
model number, equipment serial number, and a description of the part.
720 > 370
G=20
MENU
REF=INT
EXECUTE
C
T
ROSS
ECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com
Model 2083-0703
Translator
August 2015, Rev. 0
MODEL 2083
TRANSLATOR
C
ROSS
T
ECHNOLOGIES INC.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2083-0703 and is the answer not in the manual?

Questions and answers

Summary of Contents for Cross Technologies 2083-0703

  • Page 1 ALARM Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
  • Page 2: Table Of Contents

    All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages.
  • Page 3: General

    1.1 Equipment Description The 2083-0703 Translator converts 720 ± 75 MHz to 370 ± 75 MHz with a high side LO (inverted spectrum). Push button switches select the gain, and other parameters. Front panel LEDs provide indication of DC power (green), PLL alarm (red), and Remote operation (yellow).
  • Page 4: Technical Characteristics

    DB9; No or NC contact closure on Alarm Size 19 inch, 1 RU Standard Chassis 1.75” high x 16.0” deep Power 100-240 ±10% VAC, 47- 63 Hz, 25 watts maximum Technical Characteristics continued on page 5... 2083-0703 Manual, Rev. 0 Page 4 08/24/15...
  • Page 5 W18 - Ethernet; with Web Browser & SNMP W28 - Ethernet; with TCP/IP, Telnet® Contact Cross Technologies, Inc. for other options. 10˚C to 40˚C; Specifications subject to change without notice. © Cross Technologies, Inc. 2015 2083-0703 Manual, Rev. 0 Page 5...
  • Page 6: Monitor & Control Interface

    1.3 Monitor and Control Interface A) Remote Serial Interface Protocol - RS-485, RS-422 or RS-232C (selectable), 9600 baud rate, no parity, 8 data bits, 1 start bit, 1 stop bit. M&C Cable Diagram - Cross Technologies Frequency Converters Male DB-9 Female DB-9 2015/16/17 M&C Port...
  • Page 7 B) Commands - Table 1.2 lists the commands for the 2083-0703 and briefly describes them. After a command is sent the 2083-0703 sends a return “>” indicating the command has been received and executed. General Command Format - The general command format is {aaCND...}, where:...
  • Page 8: Environmental Use Information

    G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 2083-0703 Manual, Rev. 0 Page 8 08/24/15...
  • Page 9: Installation

    2.1 Mechanical The 2083-0703 consists of one RF/Controller PCB housed in a 1 RU (1.75 inch high) by 16 inch deep chassis. A switching, ± 12, +24, +5 VDC power supply provides power for the assemblies. The 2083-0703 can be secured to a rack using the 4 holes on the front panel.
  • Page 10 10 MHz 370 ±75 MHz, See Table 2.2. 47-63 Hz. Ext. Ref. Output -30 to -5 dBm output FIGURE 2.1 2083-0703 Rear Panel I/Oʼs TABLE 2.1 J10 Pinouts* TABLE 2.1 J J 10 Function RS232C RS232C TABLE 2.2 I I nput/Output...
  • Page 11: Front Panel Controls & Indicators

    Red LED indicates controls which values are being remote operation. presence of DC power an alarm condition. adjusted. Does not function in from power supply. the normal display mode. FIGURE 2.2 2083-0703 Front Panel Indicators 2083-0703 Manual, Rev. 0 Page 11 08/24/15...
  • Page 12: Operation

    2.4 Installation / Operation 2.4.1 Installing and Operating the 2083-0703, Translator Section 1. Connect a -50 dBm to -25 dBm signal to IN, J1 (Figure 2.1) 2. Connect the OUT, J2, to the external equipment. 3. Connect 100-240 ±10% VAC, 47 - 63 Hz to AC on the back panel.
  • Page 13: Menu Settings

    If programming is initiated and no operator action takes place for approximately 12 seconds (before the final press of the Menu/Execute switch) the display will revert to its previous status and you will need to start over. 2083-0703 Manual, Rev. 0 Page 13 08/24/15...
  • Page 14 A) During gain changes, the vertical movement will raise or lower the number in the direction of the arrows. B) For other functions such as REF on/off, the vertical switch will alternately turn the function on or off regardless of the direction operated. 2083-0703 Manual, Rev. 0 Page 14 08/24/15...
  • Page 15 Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to: 720 > 370 G=20 REF+INT Figure 2.4 gives the menu items and how to make changes. 2083-0703 Manual, Rev. 0 Page 15 08/24/15...
  • Page 16 SCROLL <> EXT REF Menu 3 Select External 10 MHz SCROLL PUSH BUTTON Reference (option -E) SCROLL <> Save? When go to end SAVE SETTINGS? SCROLL PUSH BUTTON FIGURE 2.4 Menu Display and Sequence 2083-0703 Manual, Rev. 0 Page 16 08/24/15...
  • Page 17: Shiloh Road Alpharetta, Georgia

    ROSS ECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com Printed in USA 2083-0703 Manual, Rev. 0 Page 17 08/24/15...

Table of Contents