Summary of Contents for Cross Technologies 3116-T71
Page 1
REMOTE POWER MUTE ALARM Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies.
1.1 Equipment Description The 3116-T71 Translator converts one of four input RF bands to one of four output RF bands in seven different translations. Front panel LEDs provide indication of DC Power, Remote, Mute and PLL Alarm. The RF to RF gain is +20 dB, maximum.
1.2 Technical Characteristics TABLE 1.0 3116-T71 Multi-Band, Block Translator* Input Characteristics 50 Ω /12 dB, 14 dB typical Impedance/Return Loss Frequency See Band Chart below Noise Figure, max. 20 dB at max. gain Input Level -30 to -10 dBm Output Characteristics 50 Ω/10 dB, 14 dB typical (see Table 2.5.1 for connector options)
The following tables summarize the commands and status queries applicable to the 3116-T71 Multi-Band Translator. PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected. Table 2.0 Model 3116-T71 M&C Commands Table 2.0: Model 3116-T71 M&C Commands Command...
Page 6
Table 2.0 Model 3116-T71 M&C Commands (continued) Table 2.0: Model 3116-T71 M&C Commands (continued) Command Syntax Description Frequency Band {aaSB} Returns {aaSBx} where: x = 1 to select band 1: in = (5.85 to 6.95 GHz) out = (3400 to 4500 MHz) x = 2 to select band 2: in = (7.90 to 8.40 GHz)
A switching ± 12, +24, +5 VDC power supply provides power for the assemblies. The 3116-T71 can be secured to a rack using the 4 holes on the front panel. Figure 2.0 shows how the 3116-T71 is assembled. POWER...
See Table 2.2 for other options. AC - POWER IN AC input for switching power supply. 100-240 ±10% VAC, 47-60 Hz. FIGURE 2.2 3116-T71 Rear Panel Inputs and Outputs TABLE 2.1 J J 10 J10 Pinouts (RS-232C/422/485*) Function Rx+ (RS-232C) Tx+ (RS-232C) TABLE 2.2 2 IF/RF...
Menu items when in controls which values are being program mode. Does not function in adjusted. Does not function in the normal display mode the normal display mode FIGURE 2.3 3116-T71 Front Panel Controls and Indicators 3116-T71 Manual, Rev. C Page 9 10/01/2015...
2.4 Installation/Operation Installing and Operating the 3116-T71 Multi-Band Block Translator: 1. Connect a -30 dBm to -10 dBm signal to RF IN (Figure 2.2). 2. Connect the RF OUTPUT, to the external equipment. 3. Connect 100-240 ±10% VAC, 47 - 63 Hz to AC connector to the front panel.
Each 3116-T71 must be configured with an appropriate IP address, Netmask, and Gateway assigned by your network manager. The 3116-T71 is set at the factory with a static address that is written on a tag attached to the unit. The device server in the 3116-T71 has a built in http based configuration manager that is used to configure network settings.
Enter the following address in a web browser to access the M & C webpage: http://<ip address of 41xx>/serial/0/setup.htm where <ip address> is the IP address of the unit. Figure 2-C (page 13) shows the product setup web page from a model 3116-T71 frequency converter. 3116-T71 Manual, Rev. C...
The next screen is a “Connect To” dialog box. Select TCP/IP (Winsock) from the “Connect” drop down menu. Enter the IP address of the 3116-T71 in the “Host address:” field and 9999 in the “Port number” field. Figure 2-D shows an example of the Hyper Terminal settings required to access the SNMP configuration menu.
Page 14
SNMP traps are not implemented. The unit will not process SNMP SET and GET requests from an SNMP manager unless the IP address associated with that manager is entered in the device server. 3116-T71 Manual, Rev. C Page 14 10/01/2015...
Page 15
Figure 2-E: Device Server Configuration Menu 3116-T71 Manual, Rev. C Page 15 10/01/2015...
3. The present band, gain, 10 MHz reference and output frequency range are shown. 5.850 -> 3.400 GHz G=10 TRANS = 2.050 GHz The unit is now operational and ready for any changes the operator may desire. 3116-T71 Manual, Rev. C Page 16 10/01/2015...
Page 17
Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to the default display: 5.850 -> 3.400 GHz G=10 TRANS = 2.050 GHz Figure 2.5 shows all the menu items and how to make changes. 3116-T71 Manual, Rev. C Page 17 10/01/2015...
Page 18
Selecting Y will save the new settings. Selecting N will revert to the previous settings. Pushing the Menu/Execute switch then takes you to: 5.850 -> 3.400 GHz G=10 TRANS = 2.050 GHz Figure 2.5 gives the menu items and how to make changes. 3116-T71 Manual, Rev. C Page 18 10/01/2015...
Page 19
Menu 8 Interior Temperature SCROLL PUSH BUTTON Save Settings? At the end or SAVE SETTINGS? SCROLL <> PUSH BUTTON when “R” is selected from any of the above menus FIGURE 2.5 Menu Display and Sequence 3116-T71 Manual, Rev. C Page 19 10/01/2015...
G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 3116-T71 Manual, Rev. C Page 20 10/01/2015...
Page 21
ROSS ECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com Printed in USA 3116-T71 Manual, Rev. C Page 21 10/01/2015...
Need help?
Do you have a question about the 3116-T71 and is the answer not in the manual?
Questions and answers