12.9 Auto Restart Control
•
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly) after power supply resumes.
•
This type of control is not applicable during ON/OFF Timer setting.
•
This control can be omitted by open the circuit of JP1 at indoor unit printed circuit board.
12.10 Indication Panel
LED
Color
Light ON
Light OFF
Note:
•
If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operation
mode judgment, or ON timer sampling.
•
If Timer LED is blinking, there is an abnormality operation occurs.
POWER
Green
Operation ON
Operation OFF
49
TIMER
Orange
Timer Setting ON
Timer Setting OFF