11.2.3

Connect the Cable to the Indoor Unit

The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.
1
Install the indoor unit on the installing holder that mounted on the wall.
2
Open the front panel and grille door by loosening the screw.
3
Cable connection to the power supply through Isolating Devices (Disconnecting means).
Connect the approved polychloroprene sheathed power supply cord 3 × 1.5 mm
o
3 × 2.5 mm
the other end of the cable to Isolating Devices (Disconnecting means).
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or
o
otherwise) is too short.
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air
o
conditioner shall be done by using approved socket and plug rated 15/16A. Wiring work to both socket
and plug must follow to national wiring standard.
4
Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.
5
Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 ×
2
1.5 mm
(1.0 ~ 1.75HP) or 4 × 2.5 mm
6
Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right
escapement.
2
(2.0HP) type designation 60245 IEC 57 or heavier cord to the terminal board, and connect
2
(2.0HP) flexible cord, type designation 60245 IEC 57 or heavier cord.