Installation Clearances - Electrolux EN19WI30LS Installation Manual

Condensing tankless gas water heater
Hide thumbs Also See for EN19WI30LS:
Table of Contents

Advertisement

6.

Installation Clearances

Before installing, check for the following:
Install in accordance with relevant building and mechanical codes, as well as any local, state or
national regulations, or in the absence of local and state codes, to the National Fuel Gas Code
ANSI Z223.1/NFPA 54 – latest edition.
Item
• Maintain the following clearances
from both combustible and
non-combustible materials.
• If possible, leave 8" (200mm) or more on
either side of the unit to facilitate inspection.
• If possible, leave 24" (600mm) or more in
front of the unit to facilitate maintenance
and service if necessary.
• If possible, leave 3" (75mm) or more
above and below the vent pipe to facilitate
inspection and repair if necessary.
<When using indoor air for combustion>
• If the unit will be installed in the vicinity of
a permanent kitchen range or stove that
has the possibility of generating steam
that contains fats or oils, use a *dividing
plate or other measure to ensure that the
unit is not exposed to air containing such
impurities.
* The dividing plate should be of
noncombustible material of a width
greater than the water heater.
WARNING
Check
Illustration
2" (50mm)
or more
Distance from
the side
8" (200mm)
or more
8" (200mm)
or more
24" (600mm)
or more
Exhaust hood
Dividing plate
Range
12" (300mm)
or more
4" (100mm)
or more
3" (75mm) or more
3" (75mm) or more
Water
heater
7