Coaxial Cable Recommendations

Caution: Careful selection of proper cable is essential to obtain the best performance from this
equipment. Vicon assumes no responsibility for poor performance when cables other than those
recommended, or equivalent, are installed. In all cases, coaxial cable impedance should be 75 ohms.
Materials
Use only a pure copper center conductor. Do not use a copper-plated steel or aluminum center conductor,
as they will result in poor quality video. Solid-core bare copper conductor is the best type, where flexing and
bending will be minimal. If severe bending and flexing is required for installation, use a stranded center
conductor. Never exceed the manufacturer's minimum bend radius specification. Use cellular (foam)
polyethylene dielectric except where heavy moisture exists. For moisture conditions, use solid polyethylene
dielectric cable with a heavy exterior insulation. The shield must be copper braid providing 95% or better
coverage.
Cable Types
The cable types listed below are the most common 75-ohm types used. They vary in size (diameter),
dielectric type and net DC resistance. The larger cable results in a lower DC resistance and better video
quality, with increased difficulty in handling and installation. Let the required picture quality and cable
distance provide a guide in choosing the best cable type. For cables other than the approved Vicon types
below, contact the manufacturers listed below. Note that "BC" refers to bare copper and "TC" refers to tinned
copper.
Cable
Belden
Type
Type No.
Type No.
RG-11/U
8213
9847
RG-6/U
9248
9804C
RG-59/U
8281*
----
RG-59/U
9259
9803
RG-59/U
9659
----
*Requires special BNC-M connector due to 0.305 nominal O.D.
Belden Inc.
Alpha Wire Company
http://www.alphawire.com/
West Penn Wire
Picture Quality
Usable picture
Clean picture
Best picture
** For longer cable runs, use a Vicon Video Amplifier to obtain a suitable picture.
Recommended Coaxial Cable Types
Alpha
West Penn
Type No.
811,4811
14 Solid BC
806,4806
18 Solid BC
815
20 Solid BC
816
22 Stranded BC
----
22 Stranded BC
http://www.belden.com/
http://www.westpenn-cdt.com/
Picture Quality vs. Cable Length
22
Type Center
Type Shield and
Conductor
% Coverage
BC braid (95%)
Foil + 61% TC braid (100%)
2 TC braids (96%)
BC braid (95%)
BC braid (95%)
(800) 235-3361
(800)-52 ALPHA (522-5742)
(800)-245-4964
Maximum Cable Run** ft (m)
RG-59/U
1100 (350)
820 (250)
400 (120)
XX181-10-02 Rev 110 VN-856V5 IP Camera
DC Resistance
ohms/1000 ft (km)
RG-6/U
RG-11/U
1500 (450)
2400 (750)
1000 (300)
1600 (500)
530 (160)
820 (250)
2.6 (8.5)
7.5 (24.6)
9.9 (32.5)
15.0 (49)
15.0 (49)