Download Print this page

Indoor Unit Fixing - Toshiba RAS-09 12EK Series Installation Manual

Hide thumbs Also See for RAS-09 12EK Series:

Advertisement

Available languages

Available languages

Right
Rear right
Bottom
Rear
right
left
Bottom left
1. Die-cutting front panel slit
With a pair of nippers, cut out the slit on the leftward or right side of the
front panel for left or right connection, and the slit on the bottom left or right
side of the front panel for bottom left or right connection.
2. Changing drain hose
For leftward connection, bottom-leftward connection and rearleftward
connection's piping, it is necessary to change the drain hose and drain
cap.
How to remove the drain hose
• The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
• When removing the drain hose, be careful of any
sharp edges the steel plate may have. Sharp
edges can cause injuries.
• To install the drain hose, insert the drain hose
fi rmly until the connection part contacts the heat
insulator, and then secure it with the original
screws.
How to remove the drain cap
Clip the drain cap with needle-nose
pliers and pull out.
How to fi x the drain cap
1) Insert a hexagon wrench
3/16 in. (4 mm) in the
center head of the cap.
2) Firmly insert the drain cap.
No gap
Insert a hexagon
wrench 3/16 in.
(4 mm).
CAUTION
Firmly insert the drain hose and drain cap; otherwise, water may leak.
In case of right or left piping
• After making slits of the front panel with a
knife or a making-off pin, cut them with a
pair of nippers or an equivalent tool.
In case of bottom right or bottom left piping
• After making slits of the front panel with a
knife or a making-off pin, cut them with a
pair of nippers or an equivalent tool.
Left-hand connection with piping
• Bend the connecting pipe so that it is laid within 1-5/8 in. (43 mm) above
the wall surface. If the connecting pipe is laid exceeding 1-5/8 in. (43 mm)
above the wall surface, the indoor unit may be unstable on the wall.
When bending the connecting pipe, make sure to use a spring bender to
avoid crushing the pipe.
1110651824-2 EN.indd 10
1110651824-2 EN.indd 10
Left
Heat insulator
Drain hose
3/16 in.
(4 mm)
Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage from the plug.
Slit
Slit
Bend the connecting pipe within a radius of 1-3/16 in. (30 mm).
To connect the pipe after the unit has been installed (fi gure)
(Forefront of fl are)
20-1/2 in.
(520 mm)
Gas side
16-9/16 in.
(420 mm)
Liquid side
R 1-3/16 in. (R 30 mm) (Use polisin
(polyethylene) core or the like for bending
pipe.)
NOTE
If the pipe is bent incorrectly, the indoor unit may be unstable on the wall.
After passing the connecting pipe through the pipe hole, connect the
connecting pipes to the refrigerant line and wrap facing tape around them.
CAUTION
• Bind the refrigerant lines (two) and connecting cable with facing tape
tightly. In case of leftward piping and rear-leftward piping, bind the
refrigerant lines (two) only with facing tape.
Refrigerant lines
Installation plate
• Carefully arrange pipes such that none of them stick out of the rear
plate of the indoor unit.
• Carefully connect the refrigerant lines and connecting pipes to one
another and cut off the insulating tape wound on the connecting pipe
to avoid double-taping at the joint; moreover, seal the joint with vinyl
tape, etc.
• Check for gas leaks before insulating.

Indoor Unit Fixing

1. Pass the pipe through the hole in the wall and hook the indoor unit on the
upper hook of the installation plate.
2. Swing the indoor unit to the right and left to confi rm that it is fi rmly hooked
up to the mounting plate.
3. While pressing the indoor unit onto the wall, hook it to the lower section
of the mounting plate. Pull the indoor unit toward you to confi rm that it is
fi rmly hooked up to the mounting plate.
Hook here.
1
1
Installation plate
2
Hook
• To detach the indoor unit from the
mounting plate, pull the indoor unit toward
you while pushing its bottom up as shown
in the fi gure.
Information
Due to piping installation, in some cases
the lower section of the indoor unit may
not completely attach to the mounting
plate. In such a case, use the provided
screws % to fi x the unit to the mounting
plate.
10
Outward form of indoor unit
Use the handle of a screwdriver, etc.
Indoor unit
Connecting cable
Press
(unhook)
Push
Push
%
%
Screw
Screw
12/13/13 4:58 PM
12/13/13 4:58 PM

Hide quick links:

Advertisement

Troubleshooting

loading

This manual is also suitable for:

Ras-09 12ea series