U-Line 3090WCWC User Manual page 71

Modular 3000 series
Table of Contents

Advertisement

USER GUIDE
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
NOTE: Air temperature does not reflect product
temperatures.
Differential
Cycle Start °F (°C) Cycle End °F (°C)
0
46 (8)
1
47 (8)
2
48 (9)
3
49 (9)
4
50 (10)
5
51 (11)
The graph below shows a unit's cooling cycle over time
with various differentials.
Set Points
Up
Can be displayed in Celsius
Down
The Set points menu contains options to modify both the
Zone and Evap set points. Changes to the zone set point
will be reflected on the main screen. Changes to the evap
set point alter the temperature the evaporator needs to
meet during a defrost cycle.
To access Set Points
1. Press
to select "Set Points".
2. Press
.
3. Press
and
to scroll through available set points.
44 (7)
43 (6)
42 (6)
41 (5)
40 (4)
39 (4)
Select
RETURN TO MENU
SET POINTS
ZONE = 38°F
EVAP = 42°F
To change set point
4. Press
, the selected set point will begin to flash.
5. Press
or
to modify the value.
6. Press
to confirm setting.
To exit the Set Points menu, press
Menu" and press
to confirm.
Factory Default
Up
Down
Factory Default will restore all settings to their factory
default.
To access Factory Default
1. Press
to select "Factory Default".
2. Press
.
To restore settings to their factory default.
3. Press
to select "Restore?" and press
4. "Restore?" will change to "Restoring..." while settings
are restored. When restoration is complete,
"Restoring..." will return to "Restore?".
To exit Factory Default, press
Menu" and press
to confirm.
u-line.com
to select "Return to
Select
RETURN TO MENU
FACTORY DEFAULT
RESTORE?
to select "Return to
Control Operation - Service 7