SERVICE MENU
In addition to a feature rich customer menu, the 3000
series also offers a service menu with the ability to fine
tune and monitor unit operation.
To initiate the Service menu hold both
seconds.
Actual Temps
Up
Can be displayed in Celsius
Down
The Actual Temp option in the service menu will display
raw thermistor readings without calculating offsets.
1. Press
to select "Actual Temps".
2. Press
.
3. Press
and
to scroll through available thermistor
readings.
To exit the Actual Temps menu, press
"Return to Menu" and press
All Errors
Up
Error ID
Down
and
for 5
Select
RETURN TO MENU
ACTUAL TEMPS
ZONE = 37°
EVAP = 52°
to select
to confirm.
Number
Of Occurrences
Select
RETURN TO MENU
ALL ERRORS
NO COMM 0
ZONE T OPEN 0
The All Errors option keeps record of any system errors.
When an error occurs it is recorded to all errors. The
number next to the error indicates the number of recorded
instances. Errors in the log may not be currently active.
The error log memory is non volatile and is persistent
should power be lost and restored to the unit. See below
for a list of logged errors and their respective descriptions.
ID
Description
No
Unit lost
Comm
communication to the
display.
L Zone T
Left Zone thermistor
Open
circuit open.
R Zone T
Right Zone thermistor
Open
circuit open.
L Evap T
Left evaporator
Open
thermistor circuit open.
R Evap T
Right evaporator
Open
thermistor circuit open.
Amb
Ambient thermistor
Thrm
circuit open.
Open
u-line.com
Solution
Check thermistor
connection to harness for
moisture or corrosion. Also
check connection where
thermistor harness
attaches to main board. If
connections are valid
replace the thermistor.
Check thermistor
connection to harness for
moisture or corrosion. Also
check connection where
thermistor harness
attaches to main board. If
connections are valid
replace the thermistor.
Check thermistor
connection to harness for
moisture or corrosion. Also
check connection where
thermistor harness
attaches to main board. If
connections are valid
replace the thermistor.
Check thermistor
connection to harness for
moisture or corrosion. Also
check connection where
thermistor harness
attaches to main board. If
connections are valid
replace the thermistor.
Check thermistor
connection to harness for
moisture or corrosion. Also
check connection where
thermistor harness
attaches to main board. If
connections are valid
replace the thermistor.
Check thermistor
connection to harness for
moisture or corrosion. Also
check connection where
thermistor harness
attaches to main board. If
connections are valid
replace the thermistor.