Error code
0x30
BT Control Status should be "Disable", but it is "Enable".
0x31
BT Control Status should be "Enable", but it is "Disable".
0x32
Power Status should be "OFF", but it is "ON".
0x33
Power Status should be "ON", but it is "OFF".
0x34
USB I/F Status should be "Attach", but it is "Detach".
0x35
USB I/F Status should be "Detach", but it is "Attach".
0x36
Wake-up Status should be non-"Assert", but it is "Assort".
0x37
Wake-up Status should be "Assert", but it is non-"Assort".
0x38
Switch Status should be "OFF", but it is "ON".
0x39
Switch Status should be "ON", but it is "OFF".
0x3a
Module dose not exist.
0x3b
Module exists. (not error)
0x3c
Command Line is wrong.
0x3d
Side band access driver is not resident.
0x3e
Bluetooth driver for DOS is not resident.
0x3f
Get Status function of Side band access driver is not normal.
0x40
No reply to inquiry
0x41
Device Descriptor can not be acquired. USB I/F is not normal.
0x42
Sideband reset timeout occurs.
0x43
Descriptor type is wrong.
0x44
Descriptor is acquired in spite of Detach condition.
0x45
Configuration file open is not normal.
0x46
Contents of Configuration file are wrong.
0x47
BD_ADDR is wrong (00)
0x48
BD_ADDR is wrong (FF)
0x49
BD_ADDR is wrong (bit0=1)
0x4a
BD_ADDR is wrong (bit1=1)
0x4b
BD_ADDR is wrong (address defined as an error)
0x4c
Suspended during Hard ware switch confirmation.
0x4d
RSSI value is less than the standard value.
0x4e
Holts
0x4f
(reserved)
Number 0x30 to 0x40 are common error codes of the test program.
PORTEGE R300 Maintenance Manua l(960-591)
Table 3-8 Common error code