9) Slowly turn on the main water supply.
10) At the nearest cold treated water tap nearby remove the faucet screen, open the faucet and let water run a few
minutes or until the system is free of any air or foreign material resulting from the plumbing work. Close the water tap
when water runs clean, then proceed to start up instructions.

Start-Up Instructions

1. Plug the valve into an approved power source.
2. When power is supplied to the control, the screen will display "INITIALIZING WAIT PLEASE" while it finds the service
position.
3. If screen is locked, press "
manual regeneration and advance the valve to the Backwash position. Open the inlet on the bypass valve slowly and
allow water to enter the unit. Allow all air to escape from the unit before turning the water on fully then allow water to
run to drain for 3-4 minutes or until all media fines are washed out of the softener.
4. Press any button to advance to the BRINE position. Check the water level in the brine tank to insure the valve is
drawing brine properly.
5. Press any button to advance to the RINSE position. Check the drain line flow. Allow the water to run for 3-4 minutes or
until the water is clear.
6. Press any button to advance to the REFILL position. Check that the valve is filling water into the brine tank. Allow the
valve to refill for the correct amount of time as displayed on the screen to insure a proper brine solution for the next
regeneration.
7.
Press any button to advance to the SERVICE position. Open the outlet valve on the bypass, then open the nearest
treated water faucet and allow the water to run until clear, close the tap and replace the faucet screen.
8. Add salt into the brine tank.
9. Program hardness and people into controller using Level One Programming Instructions.

Level I User Programming

Setting Current Time
1. If screen is locked, press "
mode and adjust CURRENT TIME.
2. Press " SET/REGEN" to adjust hours. When you have entered the change value mode, the curser will blink. Press "
UP OR DOWN" arrows to change the hour values. Press " SET/REGEN" again to accept the hour value and
or
advance to change the minutes value. Press ""
SET/REGEN" again to accept the minute values and advance to adjust the AM/PM values. Press "
to change the AM/PM value. Press " SET/REGEN" again to accept the AM/PM value and exit. When you have exited
the change value mode, the curser will stop flashing.
Setting Current Date
1. Press
DOWN" to advance to CURRENT DATE.
"
2. Using the same procedure as setting the time, press " SET/REGEN" to enter value change mode.
BRASS NUT
BLUE LOCKING CLIP
Figure 7. Brine Line Connections View
MENU" for 3 seconds to unlock. Press " SET/REGEN" and hold for 3 seconds to initiate a
MENU" for 3 seconds to unlock. Press "
or
PLASTIC NUT
3/8" PLASTIC TUBE
INSERT
MENU" again to enter level one programming
UP OR DOWN" arrows to change the minute values. Press "
UP OR DOWN"
or
6