Note. Some models are fitted with an internal heat operated switch (Thermodisc) which prevents the
fan blowing cold air. The fan will not start until the heater has warmed up (about ten minutes after
lighting on HIGH). The fan will continue to run for a few minutes after the fire is extinguished until
the firebox has cooled down.
• The flame height and fan speed can be altered by using the controls on the heater at any time. No
harm will result if you keep the flame alight but turn the fan off.

OPERATING IN MANUAL MODE

• To turn the fire on or off, simply press the ON/OFF button, checking that the display shows
MANUAL. Naturally, if your heater uses a pilot light, it must have been burning for at least 45
seconds. The flame height and fan selections will be determined by the settings on the heater
controls, but remember that the fan will not start until the fire has warmed up for about ten minutes if
your heater has a Thermodisc.
• THREE POSITION SWITCH. At any time the remote control can be disabled from operating the
heater by sliding the switch on the receiver to OFF. Sliding the switch to ON will start the heater
independently of the remote handpiece. This can be useful in the event of battery failure in the
handpiece.

AUTO MODE

In this mode the fire is automatically controlled to maintain the temperature you have selected (the
SET temperature).
• Press the ON/OFF button (if necessary), to bring up the
ON display on the screen. The flame symbol may or
may not be showing. If the remote was in PROGRAM
mode when turned off, the word PROG will show but
the OFF display may not turn to ON. Nevertheless,
proceed to the next step.
• Press the AUTO/MAN button, several times if necessary
until AUTO is displayed.
• The temperature shown on the display will be the
current room temperature.
• Press either the '+' or '–' button momentarily and the SET temperature will
show instead of the room temperature. The SET temperature display will
revert to the current ROOM temperature display after 5 seconds if no
adjustments are being made. To change the SET temperature, press the '+' or
'–' buttons as necessary until the required temperature shows. For large
changes, hold the buttons down until the required temperature is displayed.
The available range of SET temperatures is from 7 degrees C to 32 degrees
C.
• If the set temperature exceeds the current room temperature the flame symbol will show and the fire
will light (provided that the controls on the heater do not negate this action and that the pilot is alight
on ACC models). Once the room is at the required temperature, the flame will extinguish.

OPERATING IN AUTO MODE

• Make sure the pilot has been alight for at least 45 seconds (all models except EIS), the slide switch
on the receiver is set to REMOTE, that the mains supply to the receiver power pack (if fitted) is ON,
and that the flame controls on the heater are not set to PILOT or OFF.
• To operate the heater, switch ON the remote with AUTO displayed.
• To stop the heater, press the ON/OFF button.
• Place the remote control where it can sense the room temperature accurately, not near the heater,
under a strong lamp or in sunshine. If wall mounting is desired, use the slide-on bracket supplied.
• To minimise 'cycling', the signal from the remote is transmitted at three minute intervals in the
AUTO and PROG modes.
• THREE POSITION SWITCH. At any time the remote control can be disabled from operating the
heater by sliding the switch on the receiver to OFF. Sliding the switch to ON will start the heater
independently of the remote handpiece. This can be useful in the event of battery failure in the
handpiece.