Fault messages on the display

Fault code
System character-
on the dis-
istics
play
10
Constant mode
18
Constant mode
30
Burner blocked
38
Burner blocked
50
No DHW heating
51
No DHW heating
52
Burner blocked
58
No DHW heating
59
No DHW heating
Faults are indicated by a flashing fault
code with fault symbol "U" on the dis-
play.
For fault code explanations see the
following table.
Cause
Measures
Outside tempera-
Check the outside tem-
ture sensor
perature sensor and
shorted out
lead (see page 37).
Outside tempera-
Check the outside tem-
ture sensor lead
perature sensor and
broken
lead (see page 37).
Boiler water tem-
Check the boiler water
perature sensor
temperature sensor (see
shorted out
page 39).
Boiler water tem-
Check the boiler water
perature sensor
temperature sensor (see
lead broken
page 39).
Cylinder tempera-
Check the sensor (see
ture sensor
page 40).
shorted out
Outlet tempera-
Check the sensor (see
ture sensor
page 42).
shorted out
Throughput sen-
Check connections and
sor shorted out
lead; replace sensor if
required.
Cylinder tempera-
Check the sensor (see
ture sensor lead
page 40).
broken
Outlet tempera-
Check the sensor (see
ture sensor lead
page 42).
broken
Troubleshooting