4.4 Performing an Inverter Reset

Certain faults require that the inverter be reset. To perform an inverter reset (also known as a
soft reset), press and hold the Power ON/OFF button (see Figure 4-1) for approximately fi fteen
(15) seconds until the Charging/Inverting Status LED comes on and fl ashes rapidly. Once the
rapid fl ashing has begun, release the Power ON/OFF button. The Status LED will go off after the
button is released.
After the inverter reset is completed, press the Power ON/OFF button to turn the inverter ON.
Some older inverter models do not allow an inverter reset. If the inverter reset fails, you will need
to perform a power reset using the procedure below. In either case, if an internal fault does not
clear, the inverter will require repair at a Magnum Authorized Service Center (ASC).
Info: The Power ON/OFF pushbutton is a small momentary type switch which operates
by lightly pressing and releasing. Be careful not to apply too much force when pushing
or the switch might break.

4.5 Performing a Power Reset

To perform a power reset (also known as a hard reset):
1. Remove all AC power (utility or generator power) to the inverter.
2. Open all the inverter DC disconnects (or disconnect the positive battery cable to the inverter).
3. Ensure the inverter(s) and the remote are disconnected from all AC and DC power (the
remote display will be blank).
4. After the inverter(s) has been disconnected from all power for 30 seconds, reconnect the
inverter DC disconnects (or reconnect the positive battery cable) and resume operation.
Info: If DC disconnects are not used, there may be a momentary spark when the
positive battery cable is connected to the inverter's terminal. This is normal and
indicates that the inverter's internal capacitors are being charged.
© 2012 Magnum Energy, Inc.

Figure 4-1, Performing an Inverter Reset

Maintenance and Troubleshooting
1. Press and hold the Power
ON/OFF pushbutton.
2. Watch the Charging/Inverting
Status LED, after approximately
15 seconds it should come on
and fl ash rapidly to indicate the
inverter has reset. The Status LED
will go off after the pushbutton is
released.
Page 54

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms2012Ms2812Ms2024Ms4024

Table of Contents