7. AUTO CALIBRATION

7.1 Overview
AutoCal (Auto Calibration) is the PC side calibration tool that perform Rx and Tx calibration with
Agilent 8960 or other equipment. AutoCal generate calibration data by communicating with phone
and measuring equipment and write it into calibration data block of flash memory in GSM phone.
7.2 Requirements
• Microsoft Windows98/ME
• AutoCal.exe
• GSM phone
• Agilent 8960 ( or other equipment )

7.3 Menu and settings

© Ramp
• Edit
• Edit © Make bin & write
• Edit © Make bin as
• Edit- © Make RF & BB bin : Make RF(AGC, APC) bin and BB(ADC) bin separately.
: Show reference power ramp window. Reference ramp is used in APC
procedure. You can open or save reference ramp data and edit it on notepad.
Picture 3. Reference ramp window.
: Make binary file from measured calibration data and write to the
phone. The name of binaryfile is cal.bin by default. You can
change it at Option © Settings © Bin files tab.
: Make binary file as the other name.
- 75 -