Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Door Latch Interlock Removal

Remove outer door panel, see Outer Door
Removal procedure, Page 15.
Remove control panel assy, see Control
Panel Removal procedure, Page 16.
The door latch mechanism is secured to the
outer door panel by one T20 TORX screw.
With the control panel removed, remove the
screw.
If door latch has been removed the follow-
ing procedure should be used to install it for
proper alignment.
With control panel mounted to outer door
place door latch in it's proper position, then in-
stall T20 TORX into bottom of latch as shown
above in previous step. DO NOT TIGHTEN
this screw at this time. Install the two latch
screws into the upper latch mounts shown in
photo in next column. Snug these two screws
down all the way, don't overtighten. At this
time tighten the T20 TORX screw at bottom
of latch. These actions should ensure proper
latch alignment
18
!
WARNING
Remove the two upper screws at this time, they
will be installed during the outer door panel as-
sembly to the inner door assembly.
Reassemble door by reversing procedures in
previous column.
Install these two screws
snuggly