Blower Removal - Viking FDB451 Service Manual

Table of Contents

Advertisement

Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Blower Removal

Remove the four screws holding the blower
assembly to dishwasher.
Pull blower assembly out towards you slowly
as shown above. Disconnected blower motor
connection as shown below.
34
!
WARNING
The blower can be released from mount by
using a small screwdriver to release tabs,
see inset in photo below. Release tabs and
slide blower assembly and pull out of mount.
Reverse previous procedures to install the
blower.
Release
tab
©2012 Viking Preferred Service