Frost precautions

As protection against corrosion and to secure the cooling water freezing temperature to min. minus 15° Celsius as per
IMO/SOLAS requirement or lower if required from climate conditions, It is recommended to use a mixture of min. 30%
antifreeze liquid and 70% water and max. 50% antifreeze and 50% water.
However please also note when doing service on lifeboats that the mix of water and antifreeze can get aggressive and
start corrosion. If corrosion is found in the cooling system it can be caused by one of two conditions:
1.
The anti corrosion additives in the anti freezing liquid are exhausted and have evaporated.
2.
Oxidation due to incoming air causing an acid which is lowering the PH value.
Therefore and also to keep the anti freezing properties it is recommended to change the cooling water and antifreeze
every 3 years min. Please also note the details provided by your supplier of antifreeze liquid normally stated on the can.

Electrical System

The engine is equipped with a 12 volt electrical system consisting of a starter motor and an alternator, the max. charging
current of which is 50 Amp.
Electrical wiring diagram for the engine with control and instrument panels is shown later in this instruction.
The battery must never be isolated from the alternator, when the engine is running.
Warning! It is not allowed to connect additional equipment to the wiring system on the engine. Possible additional
equipment has to be connected directly to the terminals of the battery.
NOTE!
The starter must not be operated for more than 10 sec. If further operation is necessary, a pause of at least half a minute
before starting attempt is repeated.

Marine Gear

The engine is equipped with a reverse-reduction gear. The gearbox for DV48
has normally a reduction ratio of 2.63:1 for AHEAD and 1.95:1 for REVERSE.
The marine gear will need no other attendance than regular change of oil.
This to be carried out after 25 hours of operation, and then every 250 hours or
once a year.
Oil quality: "Automatic Transmission Fluid" (ATF) .
The oil change is carried out by means of the lubricating oil bilge pump fitted
on the engine.
The oil should be warm when draining.
Refill new oil to the quantity og 0.5 liters through the dipstick hole.
Check the oil level on the dipstick.
Don't forget to close the cock before starting up.
Starting instructions for BUKH Diesel Engine type DV48RME
Electric start:
1.
Switch on the main switch.
2.
Put the gear in neutral position
3.
Put the switch into "RUN" position
4.
Push the "START" button until the engine starts
Cold Start (below minus 15
Start pilot: Pull and push the pump (2) 2-3 times.
Stopping the engine: Push the "STOP" button until the
engine stops.
After the engine has stopped:Put the switch in "OFF"
position.
Filling the pressure tank (3) (if mounted):
1.
Open the cover.
2.
Put the gas cylinder on top of the valve and fill up
the tank to max. marking.
Hand Start: (If mounted):
Put gear into neutral position.
Put handle into crank claw.
Lift decompression lever (1).
Cold start with hand start (below 0
Start pilot: Pos 1 – 2 - 3
Pull and push the pump (2) 2-3 times.
Turn the start handle as quickly as possible (clockwise),
release the decompression lever, but keep on turning until the engine starts.
009W4226-R09
o
C if mounted):
o
C).