Calibrate Volume; Factory Defaults - Bunn My Cafe MCO Installation & Operating Manual

Hide thumbs Also See for My Cafe MCO:
Table of Contents

Advertisement

BE SURE THIS IS WHAT
YOU WANT TO DO BEFORE
YOU START!
3. Carefully insert USB flash drive into socket. NOTE: Make sure no other files are stored on drive other than
what you are updating.
4. Turn on power switch. Go to Import/Export screen. Press "Import". Allow files to finish loading.
5. Turn off the power switch.
6. Remove USB drive.
7. Re-install 4 screws and the top cover.
8. Turn on power switch.
NOTE: Resetting to factory defaults will reset drink settings, current history, language, units, and password. It
will not reset calibrations or clear life counter.
Parameter Name
Brew Lockout Enable
Brew Temperature (Set Point)
Ready To Brew Temperature
Hot Water Lockout
Hot Water Temperature (Ready)
Energy Saver Enable
Energy Saver Idle Temperature
Energy Saver Idle Time
Select Units
Language
Password
Parameter Name
Drink Enable
Medium Size Enable
Large Size Enable
Small Volume
Medium Volume
Large Volume
Pressure Setpoint (PSI)
Air Pump Time (sec)
Air Pump Power (%)
Parameter Name
Calibrate Volume - Volume Dispensed
Calibrate Temperature - Measured Temperature
Calibrate Pressure - Low Calibration ADC
Calibrate Pressure - High Calibration ADC
Calibrate Pressure - Calibration Range
Calibrate Refill - New Refill Value

FACTORY DEFAULTS

This will restore all machine
settings back to the factory set
default values
DEFAULT VALUES
machine settings
Default Value
Min
Enabled
200
190
195
180
Enabled
190
180
Disabled
140F/60C
4 hours
30 min
English
English
0
0
drink settings (per each drink)
Default Value
Min
Enabled
Enabled
Enabled
6.0
4.0
8.0
4.0
10.0
4.0
1.4
0.5
10
1
60
10
calibrations
Default Value
Min
10.7
6.0
0.0
180.0
415
100
540
100
1.0
1.0
825
100
Page 17
Max
Enabled/Disabled
205 This value affects the maximum ready to brew temperature
200 Required to be at least 5 degrees below the set point
Enabled/Disabled
200 Required to be at least 5 degrees below the set point
Enabled/Disabled
Options are set to "140F/60C" or heater "Off"
24 hours Moves in 30 minute increments within the range
Options are "English" or "Metric"
Options are "English", "Spanish", or "French"
9999 Setting password to "0" will disable it
Max
Enabled/Disabled
Enabled/Disabled
Enabled/Disabled
16.0 Ounces Of Water
16.0 Ounces Of Water
16.0 Ounces Of Water
2.5 Small, Medium, Large are individually settable
60 Small, Medium, Large are individually settable
80 Small, Medium, Large are individually settable
Max
16.0 Flow Meter Calibration
Measured temperature must be within 10 degrees of the Uncalibrated
Temperature to be valid, even within the min / max. Starts out with no
205.0
calibration given (and thus no offset).
900
900
5.0 Calibration PSI
1023
This will restore all machine
settings back to the factory set
default values
20%
Notes
Notes
Notes
49251.0 062014