23.11.2005 / Page 2
Doc. No: 4812 728 12698

Technical data

Dimension
Height
Width
Depth
Weight
Electronic boards
Service boards
Serial boards
Programing of version and programmed control
board, see „Service" and „Data set" on rating
plate of inner door:
UCB (User/Control board) 739832
Data set
Basic UCB (User/Control board) not programmed
see on the board itself
Succession of programs
Programs
Succession
Options
Half load program
Program information
Start indicator
All programs will be locked after start. Changing
the program or finishing the program will be
possible only after pressing the start button for
longer then 1.5 sec. (Break by customer)
A switching off the appliance or unplug the
appliance for a while, this will frozen the program
step and later on, the program continuos on the
same position.
Exception: Switching off the appliance or unplug
the appliance during the drying phase, this will lead
directly to the end of the program.
ADP 6600 WH
8542 660 53950
cm ± 1.4
85,0
59.7
cm
61.0
cm
58
kg
see spare part list
see on the boards itself
739822
4619 727 33182
see program diagram
P1a-P3a-P5d-P7a-P12a
Whirlpool Europe
Customer Service
Water Volume at permanent spray system
Water
Regeneration
Back rinse 3x
Prewash
Main wash
Intermediate rinse 1
Intermediate rinse 2
Clear rinse
Safety/ overflow
Measuring the level
Remove the coarse sieve, put in a measuring
meter into the sump, measure the hight of the
water level.
Detergent max.
Pre-wash
Main-wash
Rinse aid
6 Dosage steps
Water pressure
Inlet pressure
Spray pump pressure
Rotations
Spray pump motor
Drain pump motor
Spray arm lower
Spray arm upper
S E R V I C E
Volume
Level
0.3 l
15 mm
1.0 l
60 mm
4.8 l
120 mm
4.2 l
118 mm
4.2 l
118 mm
4.2 l
118 mm
4.2 l
118 mm
8.5 l
141 mm
3
10
cm
3
40
cm
3
135
cm
1 - 6
ml
0.3 - 10
bar
0.4
bar
2800
RPM
3000
RPM
30 - 40
RPM
30 - 40
RPM