Technical Data - Whirlpool AGB 372/WP Instructions For Installation, Use And Maintenance Manual

Advertisement

- Read the warnings contained in this manual carefully as
they provide important information concerning safety
during the installation, use and maintenance of the ap-
pliance.
- Keep these instructions carefully!
- Only personnel trained for its specific use should use the
equipment.
-
Keep the appliance under control during use.
-
The appliance should be used only for the purpose for
which it has been specifically designed; other uses are im-
proper and hence dangerous.
-
During operation surfaces can become hot and require
special operation.
-
Unplug the appliance in case of failures or improper
These appliances are used for professional purposes. Installation, re-
pair and use must be carried out by expert personnel.
The data plate is located on the front part of the appliance (on the
control panel).
Description
("A" as end letter = pressure kettle)
Width (A)
mm
Depth (B)
mm
Height (C)
mm
Vat diameter
mm
Vat height
mm
Total volume
lt
Usable volume
lt
Voltage/Input
Power
kW
Power cable
Hot water connection
mm
Cold water connection
mm
Water pressure
kPa
Jacket volume
lt
Jacket pressure
bar
033 - 03 - Electric kettles
GENERAL REMINDERS
2 - CHARACTERISTICS OF THE APPLIANCES

3 - TECHNICAL DATA

AGB 372/WP AGB 375/WP
AGB 377/WP
800
800
900
900
875
875
600
600
415
540
110
145
100
135
3N 400V / 50hz
3N 400V / 50hz
16
18
5 x 2.5 mm
5 x 6 mm
2
2
10
10
10
10
50 - 300
50 - 300
0.5
0.5
operation.
-
Apply exclusively to a service centre for repairs or
maintenance.
-
Any important information about the appliance requi-
red for technical service is contained in the technical data
plate (see figure "View of appliance").
-
If technical assistance is required, the trouble must be
described in as much detail as possible, so that a service
technician will be able to understand the nature of the pro-
blem.
-
Gloves should be worn to protect the hands during in-
stallation and maintenance operations.
Warning! : Follow the fire prevention regulations very
carefully.
CAT/KAT
II2H3B/P
II2H3+
II2H3+
II2L3B/P
II2ELL3B/P
TIPO/TYPE
II2E+3+
MOD.
II2H3B/P
ART.
I2E
N.
II2H3B/P
N.
II2H3+
Qn kW
I3B/P
MOD.
m
3
/h
I3+
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: - Geschuckt voor:
V AC
kW
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
AGB 384/WP
AGB 390/WP
AGB 386/WP
AGB 392/WP
1000
1150
1200
1300
875
875
750
900
520
570
215
330
200
300
3N 400V / 50hz
3N 400V / 50hz
32
36
5 x 10 mm
5 x 10 mm
2
2
10
10
10
10
50 - 300
50 - 300
0.5
0.5
5
GAS/GAZ
G30
G31
G20
G25
P mbar
30
30
20
-
SE
FI
P mbar
30
37
20
-
IT
CH
P mbar
28
37
20
-
ES
IE
P mbar
30
30
-
25
NL
P mbar
50
50
20
20
DE
P mbar
28
37
20
25
FR
BE
P mbar
50
50
20
-
AT
CH
P mbar
-
-
20
-
LU
P mbar
30
30
-
-
EE
LV
P mbar
28
37
20
-
EE
LV
P mbar
30
30
-
-
NO
MT
P mbar
28
37
-
-
CY
Hz
AGB 396/WP AGB 399/WP
1250
800
1400
900
875
530
900
600
790
415
535
110
500
100
3N 400V / 50hz
3N 400V / 50hz
36
16
5 x 10 mm
5 x 2.5 mm
2
2
10
10
10
10
50 - 300
50 - 300
0.5
0.5
DK
CZ
SK
SI
PT
GB
GR
LT
LT
CY
IS
HU
MADE IN ITALY
AGB 401/WP
800
900
530
600
540
140
135
3N 400V / 50hz
18
5 x 6 mm
2
10
10
50 - 300
0.5

Advertisement