Download Print this page

S E R V I C E Whirlpool Europe; Whirlpool Europe Customer Services 000 270; Technical Data - Whirlpool 000 270 52 Service Manual

Advertisement

16.07 .2001 / Page 2
Doc. No: 4812 718 16741

Technical data

Dimension of Built In appliances Full Door
Height
Width
Depth
Weight
Wooden door for Full Door appliances
Thickness min.
Thickness max.
Width min.
Width max.
Height min.
Height max.
Weight min.
Weight max.
Max. stick out over lower
edge of appliance door
Height of plinth min.
Electronic boards
Service boards
Serial boards
DLB
UB
Programing of version and programmed control
board, see „Service" and „Data set" on rating
plate of inner door:
CB programmed
Data set
Basic control board, not programmed see on the
board itself
Succession of programs
Programs
Succession
A1a - A3a - A4a - A5d - A6a - A7a
Datas Energy Label
Reference program
Energy Performance
Cleaning Performance
Drying Performance
Alarms
Refill rinse aid
Refill salt
000 270 52
8542 406 01710
82.0 - 87 .0 cm
59.7
cm
55.5
cm
53
kg
16
mm
20
mm
592
mm
595
mm
620
mm
718
mm
2.5
kg
6.5
kg
92
mm
93
mm
see spare part list
see on the boards itself
092221
4619 720 94322
448871
448861
4619 724 17441
see program diagram
A5b
B
A
C
Whirlpool Europe
Customer Service
Options
Zone washing
Program information
End - Acoustic signal
All programs will be locked after start. Changing
the program or finishing the program will be
possible only after pressing the start button for
longer then 1.5 sec. (Break by customer)
A switching off the appliance or unplug the
appliance for a while, this will frozen the program
step and later on, the program continuos on the
same position.
Exception: Switching off the appliance or unplug
the appliance during the drying phase, this will lead
directly to the end of the program.
Water Volume at alternating spray system
Volume at alternating spray system (same level
when selected zone washing as in the normal
programs)
Water
Regeneration
Back rinse 3x
Prewash
Main wash
Intermediate rinse 1
Intermediate rinse 2
Clear rinse
Safety/ overflow
Measuring the level
Remove the coarse sieve, put in a measuring
meter into the sump, measure the hight of the
water level.
Detergent max.
Pre-wash
Main-wash
Rinse aid
6 Dosage steps
S E R V I C E
Volume
Level
0.3 l
15 mm
1.0 l
60 mm
3.9 l
120 mm
3.2 l
118 mm
3.2 l
118 mm
3.2 l
118 mm
3.2 l
118 mm
8.5 l
141 mm
3
10
cm
3
40
cm
3
135
cm
1 - 6
ml