Heater Placement Requirements; Floor Protection Requirements; Gas Line Installation; Gas Inlet Pressure - Lopi allegiance Owner's Manual

Direct vent
Table of Contents

Advertisement

Installation

Heater Placement Requirements

Heater must be installed on a level surface capable of supporting the heater and vent
Due to the high temperature of the heater, it should be located out of traffic and away from
furniture and draperies.
?
When placed in a location where the floor to ceiling height is under 7 feet, the installation is
considered an alcove and must meet the following requirements:
The heater must not be placed so the vents below or above the door, along the sides of heater, or
along the back of the heater can become blocked.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.

Floor Protection Requirements

When the stove is installed directly on carpeting, vinyl or other combustible material other than
wood flooring or a high pressure laminate wood floor, the stove must be installed on a metal or
wood protection panel extending the full width and depth of the heater (Minimum 22-1/8" wide by
15-5/8" deep).

Gas Line Installation

!
The gas line must be installed in accordance with all local codes, if any; if not, follow current ANSI
Z223.1 or NFPA 54.
!
The heater and gas control valve must be disconnected from the gas
supply piping during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.45 kPA). For pressures under 1/2
psig (3.45 kPA), isolate the gas supply piping by closing the manual
shutoff valve.
This heater is designed for natural gas but can be converted to propane.
Check sticker on top of gas control valve to verify correct fuel.
Leak test all gas line joints and the gas control valve prior to and after
starting the heater.
The gas inlet accepts a 3/8" F.P.T. Fitting
The location of the gas inlet is shown below
A manual shutoff valve is required for installation (it must be located
within 3' of the heater). T-Handle gas cocks are required in
Massachusetts in compliance with code 248CMR.
Installation must be performed by a qualified installer, service agency or
the gas supplier (In Massachusetts a licensed plumber/gasfitter).

Gas Inlet Pressure

With the heater off, the inlet pressure must meet the requirements listed in the table below
?
If the pressure is not sufficient, make sure the piping used is large enough and the total gas load
for the residence does not exceed the amount supplied.
?
The supply regulator (the regulator that attaches directly to the residence inlet or to the propane
tank) should supply gas at the suggested input pressure listed below. Contact the local gas
supplier if the regulator is at an improper pressure.
Travis Industries
The alcove floor to ceiling height must be at least 58" tall
The alcove must not be more than 45" deep before the ceiling returns to 7'
The alcove must be at least 46-3/4" wide
Standard Input Pressure
Natural Gas
7" W.C. (1.74 Kpa)
Pr o p an e
13" W.C. (2.73 Kpa)
(for qualified installers only)
4041220
7
1/4"
6-1/8"
2-7/8"
9 3 5 0 8 1 2 3