Amplifier Configuration; Servo-Amplifier Fuses; Table 11: Amplifier Configuration; Table 12: Amplifier Fuses - Quin Q-drive Installation & User Manual

Servo amplifier
Table of Contents

Advertisement

Q-Drive Installation Manual
10.3

Amplifier Configuration

The location of the solder bridges and jumper links used for configuration and the fuse
locations is given in Figure 26. on page 64 .
Name
Element
SAD
Solder bridge
VITCRT
Solder bridge
BD1
Solder bridge
BD2
BD3
Solder bridge
BD4
BDOUT
INCABS
Solder bridge
10.4

Servo-amplifier fuses

The following fuses are factory fitted on all Q-Drive units, the location of the fuses can
be found in Figure 26. on page 64
Servo-amplifier type
DC-BUS
Braking module
Supply
DC-BUS Fuse (F1)
"Littlefuse 326" are used on the DC-BUS. Dimensions: 6,3 x 32 mm.
Braking module fuse (FFR)
For units type QDV-1-6, "Wickmann 19194" type fuses are used.
Dimensions: 5 x 20 mm.
Page 58
Function
1-2: analogue command voltage (default)
2-3: numeric command voltage through RS 232 serial
link or through synchronous link (option)
1-2: speed regulation (standard)
2-3: current regulation
RS 232 serial link baud rate:
only BD2 soldered: 9600 Bd (default)
only BD1 soldered: 19200 Bd
Synchronous link (option):
only BD3 and BDOUT soldered: internal clock at
38400 Hz
only BD4 soldered: external clock
2-3: encoder simulation available at the encoder
output connector (default)
1-2: absolute position available through the serial link
(option)

Table 11: Amplifier Configuration

QDV-1-6
10 AT
4 AF
1 AT

Table 12: Amplifier Fuses

QDV-1-10
QDV-1-18
15 AT
20 AT
5 AF
8 AF
1 AT
1 AT
Copyright © 1996 Quin Systems Ltd.