Wiring And Connectors; Cable Lengths And Cross-Sections; Table 3: Cable Sizes - Quin Q-drive Installation & User Manual

Servo amplifier
Table of Contents

Advertisement

Q-Drive Installation Manual
4.1.1

Wiring and connectors

The wiring of the Q-Drive series of servo-amplifiers must be carried out according to
the schematics in these instructions. Local wiring regulations must be observed.
Special attention should be paid with respect to wiring rules regarding ground, earth and
neutral.
The earth wire to the amplifier, motor and housing must be as short as possible and
connected to a common earth point.
The complete wiring plan is represented in on the next page.
4.1.2

Cable lengths and cross-sections

Quin Systems recommend that the following cable cross-sections are used:
Supply voltage
Motor
Earth
Command signals
Page 14
Units
PQD506
2
1.50
mm
2
1.50
mm
2
1.50
mm
2
0.18
mm

Table 3: Cable Sizes

PQD510
PQD518
2.50
4.00
2.50
4.00
2.50
4.00
0.18
0.18
Copyright © 1996 Quin Systems Ltd.