Specifications - Waterstage WO*G112LCT Installation And Operating Manual

Air to water heat pump split integrated dhw type
Hide thumbs Also See for WO*G112LCT:
Table of Contents

Advertisement

Air to Water Heat Pump (Split integrated DHW type)
1 .3

Specifications

Designation model Waterstage High Power
Nominal heating performances (outdoor temperature / initial temperature)
Heat output
+7 °C / +35 °C - Floor heating system
-7 °C / +35 °C - Floor heating system
+7 °C / +45 °C - Low temperature radiator
-7 °C / +45 °C - Low temperature radiator
+7 °C / +55 °C - Radiator
-7 °C / +55 °C - Radiator
Power absorbed
+7 °C / +35 °C - Floor heating system
-7 °C / +35 °C - Floor heating system
+7 °C / +45 °C - Low temperature radiator
-7 °C / +45 °C - Low temperature radiator
+7 °C / +55 °C - Radiator
-7 °C / +55 °C - Radiator
Coefficient of performance (COP)
Electrical characteristics
Supply voltage (50 HZ)
Maximum current for appliance
Nominal current
Maximum current of the electrical back-ups (heating)
Power of the electrical back-ups (heating)
Real power absorbed by the fan
Real power absorbed by the circulation pump
Maximum power absorption by the outdoor unit
Electrical back-up power DHW
Hydraulic circuit
Maximum operating pressure Heating
Maximum operating pressure Domestic hot water tank
Hydraulic system flow rate 4°C<Δt<8°C (nominal conditions) min./max.
Various
Weight of outdoor unit
Weight of hydraulic unit (empty / full of water)
Water capacity of the hydraulic unit / the domestic tank
Noise level at 1 m
(hydraulic unit)
1
Sound power level according to EN 12102
Noise level at 5 m
(outdoor unit)
1
Sound power level according to EN 12102
Heating system operating limits
Outdoor temperature mini/maxi
Initial max. heating water temperature Floor heating system
Initial max. heating water temperature Low temperature radiator
Refrigeration circuit
Diameter of gas pipes
Diameter of liquid pipes
Factory charge of refrigerant R410A
Maximum operating pressure
Minimum length of pipes
Maximum length of pipes
4
Maximum length of pipes
/ Maximum level difference
5
Sound pressure level in (x)m of the device, 1,5m of the ground, the open field.
1
The sound power level is a laboratory measure of the emitted sound power but
2
contrary to the noise level, it doesn't correspond to the measure of the felt.
Installation and operating manual "1586 - EN"
(+7 °C / + 35 °C)
(hydraulic unit)
2
(outdoor unit)
2
3
5
11
14
Single phase
Single phase
kW
10,80
13,50
kW
10,80
12,00
kW
9,23
11,54
kW
9,16
11,45
kW
7,74
9,67
kW
7,51
9,25
2,54
3,23
kW
4,32
5,08
kW
2,84
3,72
kW
4,58
5,92
kW
3,13
4,03
kW
4,56
5,65
kW
4,25
4,18
V
230
A
22
25
A
11,4
14,2
A
13,05 / 26,1
kW
ajustable 3 or 6 kW (Single phase)
W
2x100
W
W
5060
5750
W
bar
bar
l/h
1170 / 2340
1460 / 2920
kg
92
kg
l
dB
dB
dB
42
43
dB
69
70
°C
°C
°C
inches
inches
g
bar
m
m
m
Refrigerant R410A (as per the standard EN 378.1).
3
Factory charge of refrigerant R410A.
4
Taking into account the possible additional load of refrigerant R410A (see
5
11
14
16
3-phase
3-phase
10,80
13,50
10,80
13,00
10,10
12,60
10,02
12,50
9,48
11,80
9,20
10,60
2,51
3,20
4,28
5,18
3,01
3,81
4,63
6,00
3,60
4,61
5,08
6,04
4,30
4,22
400
8,5
9,5
3,7
4,8
13
9 kW (3-phase)
2x104
70
5865
6555
1500
3
10
1170 / 2340
1460 / 2920
1650 / 3290
99
152/ 366
24 / 190
39
46
39
41
66
68
-25 / +35
45
60
5/8
3/8
2500
41,5
5
15
20 / 15
3-phase
15,17
13,50
13,00
13,00
12,96
11,90
3,70
5,40
4,00
6,37
5,14
6,88
4,10
10,5
5,5
7245
42
69
page 21)
- 5 -