Waterstage WO*G112LCT Installation And Operating Manual page 46

Air to water heat pump split integrated dhw type
Hide thumbs Also See for WO*G112LCT:
Table of Contents

Advertisement

Air to Water Heat Pump (Split integrated DHW type)
Line
Function
Domestic hot water
1610
U
Nominal setpoint
The backup electrical system is required to reach this level.
1612
U
Reduced setting
1620
I
Release of DHW load
24h / day: The temperature of the DHW is constantly maintained at the DHW comfort setting.
Heating circuit time programme: The DHW is produced according to the programming for the ambient temperature
(with 1 hour in advance when switched on).
Programme 4 / DHW: The DHW programme is separate form the heating circuit programme.
Off-peak tariff* : The electrical backup heating is only authorised to operate during the off-peak period.
T'prog 4/DHW or low-tariff *: The electrical backup heating is authorised to operate during the comfort period or off peak.
* - Connect the "Power Provider" contact to input EX2 (see
the electric back-ups for the DHW tank are subject to the power supplier's tariffs. Switching on the electric back-up for
the DHW tank is only authorised during off-peak hours.
1640
I
Legionella function
1641
I
Legionella function periodically
1642
S
Legionella function weekday
Swimming pool (Only with swimming pool kit option)
2056
U
Setpoint source heating
Heat pump (HP)
2803
S
Overrun time cond pump
2843
S
Compressor off time min
2844
S
Switch-off temp max
2862
S
Locking time stage 2 / mod
2873
S
Compressor mod run time
2882
S
Release integr electric flow
2884
S
Release el flow below OT
Electrical release - start-up with outside
temperature
2886
S
Compensation heat deficit
S
2916
Max setpoint HP DHW charg
2920
S
With electrical utility lock (EX1)
Released : HP = ON _ Back-up DHW = off _ 1st back-up HP = off _ 2nd back-up HP = off _ Boiler = ON
Locked (Blocked on standby) : HP = off _ Back-up DHW = off _ 1st back-up HP = off _ 2nd back-up HP = off _
Boiler = ON
- 46 -
Setting range
or display
Reduced setpoint (line 1612)...
65 °C
8 °C
Nominal setting (line 1610)
24h / day
Heating circuit time programme
Programme 4 / DHW
Off-peak tariff (Off-peak)
Programme 4 / DHW
and Off-peak
figure 39, page
31). In the case of a day /night contract,
Off, Periodically (depending line
setting 1641), Fixed weekday
(depending line setting 1642)
1 to 7
Monday, Tuesday,...
8
35 °C
8... 240 s
0... 120 min
8
100 °C
0... 40 min
10... 600 s
0... 500 °Cmin
-30... 30 °C
Off, On,
Only with floor curing fct
8
80 °C
Locked (Blocked on standby),
Released
Installation and operating manual "1586 - EN"
Setting
Basic
increment
setting
1
55 °C
1
40 °C
Programme
4 / DHW
Off
1 day
7
Saturday
22 °C
1 s
240s
1 °C
8 min
1 °C
75 °C
1 min
5 min
1 s
240 s
1 °Cmin
100 °Cmin
2 °C
Off
60 °C
Released