Specifications - A.O. Smith T-M32 Service Manual

Table of Contents

Advertisement

1. Specifications

Unit Model
Unit dimensions
Weight
Max
INPUT
BTU/h
Min
Combustion System
Installation
Fan motor
Max
Manifold
Pressure*
Min
Flow rate
Available set temp.
Temperature
dipswitch setting
Bypass valve
Thermistors
Available remote
controller
PCB Model
Indicators
Power supply
control
Freeze protection
Self-combustion
improvement
Easy-link system
Multi-unit system
*The manifold pressure measurement is base on conditions without front cover.
T-M32 / T-M32 ASME
H 23.6"×W 18.5"×D 8.9"
Power vent
Indoor, Outdoor, Direct vent
PWM Turbo fan
LP 3.4" WC
Natural 2.3"W.C
LP 0.7 WC
Natural 0.5" WC
0.5 to 9.0 GPM
100°F to 185°F
default set 120 °F
100°F, 115°F, 120°F, 135°F, 145°F, 155°F, 165°F, 185°F
3 thermistors (In, Out, Mixing)
T-M32 (Part # EM376)
Red LED on PCB during operation & 7-seg LED
GFI & Surge absorber
Ceramic heaters and Auto- FM system
Air Fuel Ratio detection system
3
T-M32 / T-M32 ASME Service manual
59 lbs.
240,000
24,000
Yes
TM-RE30
Yes
Yes
CONFIDENTIAL
Ver. 1.03