Access To The Gas System - Chaffoteaux & Maury BRITONY SX 14 FF Installation, Servicing And User's Manual

Fan flued instantaneous multipoint water heater
Table of Contents

Advertisement

7.5 Access to the Gas System

7.5.1 Removing the gas valve
1. Carry out steps 7.1.1 & 7.3.1;
2. Remove the microswitch as in
step 7.4.4 (Fig. 83);
5. Remove the 2 screws U between
the electrical box and the gas
valve (Fig. 86);
3. Disconnect the gas valve (Fig.
84);
F
. 83
IG
6. Remove the 2 screws E between
the elbow and the gas valve (Fig.
87);
U
F
. 86
IG
F
. 84
IG
E
F
. 87
IG
28
4. Remove the water valve as in
step 7.3.3 (Fig. 85);
7. Remove the 2 screws V securing
the gas valve on the chassis
(Fig. 88);
V
F
. 85
IG
F
. 88
IG

Advertisement

Table of Contents
loading

Table of Contents