Gas Connection
-
Fit the gas service cock provided using the fine
filter/washer
to seal the connection. Fit the nut and
olive onto the 15 mm gas supply pipe and tighten.
- Test the complete
gas installation
for soundness
and purge.
Water connections
-
Remove the plastic covers protecting
the water in-
let and the water outlet connections.
- Fit the water service cock provided to the right
hand connection
at the bottom
of the appliance
using the coarse filter/washer
to seal the connec-
tion.
- Fit the nuts and olives onto the supply and delivery
pipes.
- Connect the inlet supply to the water service cock
and tighten.
- The water service cock supplied with the appliance
incorporates
a drain plug.
- Ensure that all water connections
are fully tighte-
ned.
3.8.1. Pressure Switch
-
Connect the wires at the top of the appliance to
the pressure switch.
- The
grey
wire is connected to normally closed (NC
I) contact.
- The
pink
wire to the normally open (NO 2) contact.
- The
violet
wire to the common (P) contact.
- Fit the flue turret
cover passing the wire through
one of the slots provided
and secure with the
screws provided.
- See figure.
3.82.
Mains Connection
-
Pass 0.75 mm2 heat resisting cable through
cable
gland.
- The earth wire (green yellow) must be connected
to the earth pillar ( +
L
- The live (brown)
and neutral
(blue) should
be
connected as indicated into the terminal block.
- Check that component
plugs are pushed home.
- Check for continuity,
polarity and earthing.
'