Dunkirk 95M-200 Control Manual And Troubleshooting Manual page 23

Hide thumbs Also See for 95M-200:
Table of Contents

Advertisement

Display shows Para until a key is
pressed
Press and Hold Key(s) in BLACK
[MODE]
[STEP]
[STORE] [+] [-]
[MODE] [STEP] [STORE]
[MODE] [STEP] [STORE] [+]
[MODE] [STEP]
[STORE]
[MODE]
[STEP] [STORE] [+] [-]
DHW Setting: Left digit
shows "1" and right
digit shows "140." DO
NOT change this setting.
Performance could be
unreliable. Set DHW tank
temp. on DHW aquastat.
(1) After the [STORE] button is pressed, the set value will fl ash twice to confi rm the change. Change will take effect after you leave
Parameter Mode.
10 - USER INTERFACE QUICK REFERENCE
Press [MODE] button 1 time from Standby Mode.
then displays Parameter and Current Status.
Para
(1)
Duration
Step to next parameter (continue tapping
Step to
Tap
change to 1, 2, 3, or 4)
Increase setting
Tap
[+]
[-]
FAST increase setting
Hold
Decrease setting
Tap
[-]
FAST Decrease setting
Hold
Store current setting (tap this key after
[+] [-]
Tap
setting the parameter as desired)
Next mode (info)
Tap
DHW Setup: Left digit shows "2"
and right digit should show "01."
DO NOT change this setting. DHW
performance could be unreliable
or unsafe.
PARAMETER MODE
Result
Space Heating (SH)
Setup: Left digit shows
"3" and right digit should
show "01." DO NOT
change this setting as it
might affect performance
of your boiler.
23
DHW Setting
DHW Setup
Space Heating Setup
Outlet Temperature
(See details below)
SH Temperature: Left digit shows "4"
and right three digits show target outlet
water temp. (at 32°F outside if outdoor
sensor is used). Adjust to desired
settings with + and - keys.
1 180
Display
1 140
2
01
3
01
4 190
Info