Drilling Template (Rear Flue Application)
1.
fl ow
. Safet
al e
. Domestic hot water outlet
.
as suppl
. Domestic hot water inlet
.
return
Select suitable mounting position
boiler, using the template mark fl ue outlet
and boiler mounting points. Drill two
10mm holes 90mm deep to accept the
wall plugs, fi t wall plugs. Fit two special
wall plugs on the wall as described in the
fi g. 26a. Fasten the wall bracket to the
wall using an antitheft nut on the right
side and a standard nut (M8) on the
left side. Mount the boiler on the wall
bracket and fi x using an antitheft nut on
the left side and a standard nut (M8) on
the right side.
Using a core drill cut a 118mm diameter
hole for the fl ue.
Fig. 26a
280
270
Ø118
Ø 3/4"
Ø 1/2"
Ø 1/2"
Ø 1/2"
Ø 1/2"
1 2 3
4
5
125 min
21 min
Ø 3/4"
6
5 min
Fig. 26b
for
21