Self-check
If you cannot divide the self-diagnosis lamp (blinking 2 times, 3 times, 4 times, 5 times) between the
electrical installation and compressor, conduct the following [self-check].
(The product will energize the intelligent power module on its own and check the inverter.)
・How to conduct self-check diagnosis
 1. Shut down the power supply. (Wait at least 10 minutes until the DC voltage discharges.)
 2. Pull out the CN30.
 3. Turn the power back on and perform air purification on the indoor unit. (The LD302 blinks once.)
 4. Press the [test switch] for at least 1 second.
  ・Energize the IPM and compressor motor in that order and check for short-circuits and openness.
 5. Displaying the self-check diagnosis results
  ・When the self-check is over, the "LD303" will go on. The diagnosis findings are as shown in the
    table below.
『S E L F −C H E C K』 I S F I N I S H E D
SELF-DIAGNOSIS LIGHTING MODE
L
L
L
D
D
D
SELF-DIA-
3
3
3
0
0
0
GNOSIS NAME
1
2
3
RED
RED
RED
NOT ELECTRIFICAL 
DEFECTIVE
ONCE
PEAK CURRENT CUT
SIGNAL DETECTION
2TIMES
ABNORMAL COMP-
RESSER CURRENT 
7TIMES
ABNORMAL DC 
VOLTAGE 
10TIMES
EEPROM READING 
ERROR
13TIMES
※ E X AM P L E O F
BLINKING 
(5 TIMES)
If the judgment indicates an abnormality, check the connection line. If nothing is loose or otherwise
defective, follow the correction procedure and replace the defective parts. If the electrical installation
proves to be trouble-free (blinking once), use it after securely inserting the CN30.
※If you forget to insert the CN30, the indoor timer lamp will blink 12 times and the product will not run.
:BLINKING
:LIGHTING
CORRECTION CONTENTS
EXCHANGE OF COMPRESSORS
EXCHANGE OF ELECTRICAL 
CONTROLLING BOX.
・ C H E C K T H E C OM P R E S S E R
CONNECTOR 
・ E X C H A N G E O F E L E C T R I C A L  
CONTROLLING BOX.
EXCHANGE OF ELECTRICAL 
CONTROLLING BOX.
EXCHANGE OF ELECTRICAL 
CONTROLLING BOX.
  ・ ・ L I G H T S F O R 0 . 2 5
2SEC.
   SEC. AT INTERVAL
   OF 0.25 SEC.
TEST SWITCH
DC VOLTAGE 
MESUREMENT
POINT(+)
DC VOLTAGE 
MESUREMENT 
POINT(-)
IPM
OUTDOOR FAN 
MOTOR CONNECTOR
:OFF
CONTROL P.W.B.
LD301
LD302
LD303
CN30 FOR SELF-CHECK 
– 270 –

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-18sx8

Table of Contents