14. Timer lamp blinking: blinking 12 times
[Situation] The timer blinks 12 times and the product will not run.
[Estimated failure locations] ・Erroneous connection in the indoor-outdoor connection line (F cable)
[Cautions] ・When lines A and B of F cable are erroneously connected (crossed), the product may not
enter self-diagnosis display mode. If the self-diagnosis memory stores data about "timer
lamp blinked 12 times," then, just in case, check if the F cable is not erroneously connected.
・Detecting this failure mode turns off the power relay 3 minutes later and blocks the power
supply to the outdoor unit.
[Diagnosis flow]
Initiating troubleshooting
Is the F cable connection free from errors?
Is the CN30 securely inserted into
the outdoor board?
Press the START/STOP button on the remote control
unit and start the product.
Are terminals A and B of the terminal board of the
electrical installation of the outdoor unit subjected to
220-230 V AC?
※ Take measurements within 3 minutes after remote
control operation.
Are terminals A and B of the terminal board of the electrical
installation of the indoor unit subjected to 220-230V AC?
※ Take measurements within 3 minutes after remote control
operation.
Replace the "indoor electrical installation."
15. Timer lamp blinking: blinking 13 times
[Situation]
The timer lamp blinks 13 times and the product will not run.
[Estimated failure location] ・EEPROM, microcomputer
[Diagnosis flow]
Replace the "indoor electrical installation."
・Wire break or poor insertion of the indoor-outdoor connection line (F cable)
・Electrical installation in the outdoor unit
・Communication error due to noise in other home electronics
※This does not constitute a failure in the air-conditioner.
Yes
Yes
No
No
No
Correct the F cable connection.
No
Yes
Check the electrical installation
of the outdoor unit.
Yes
Double-check the F cable for erroneous connection,
wire break, and poor insertion and correct the
nonconforming parts.
– 260 –
Correct the connector.